+-------------------------------------+ | Product : NuDesign Visual MIBuilder | +-------------------------------------+ 1.0 Eval Restriction --------------------- Eval version of this application only allows the user to save a MIB file or export to a yang file, if it has 25 or fewer nodes. 2.0 Contact Information ------------------------ Tel: (416) 737-0328 Fax: (416) 445-9101 Email: contact@ ndt - inc.com Web: http://www.ndt-inc.com 3.0 Version History ----------------------- version 6.3.0 July 15, 2020 - DisplayString is properly imported from 'snmpv2-tc' in the generated yang modules. version 6.2.0 Feb 23, 2017 - Yang output, bug fixes - fixed reading in of very large mib file - added prefixes.txt file that provides yang module names to yang module prefixes mapping - updated copyright statement version 5.2.0 July 2, 2013 - Yang output now includes deviations modules for writtable objects version 5.1.1 Feb 7, 2013 - Release including export of mibs to yang format. version 4.9.1 Dec 27, 2012 - Internal release for outputting SMIv2 to yang format. version 4.9.0 October 14, 2010 - Produces xmc file for consumption by NuDesign xManagerBuilder product. - Added link to the NuDesign website from About box. version 4.8.0 September 26, 2010 - Module Identity was not producing correct ASN.1 for large child numbers. version 4.7.8 July 27, 2009 - Items in the notification type were not showing up if they belonged to a different module. version 4.7.7 Jan 5, 2009 - Allowed DEFAULT field for read-only objects version 4.7.6 Oct 29, 2008 - Property window was not resizing. version 4.7.5 Oct 9, 2008 - The objects list within Noitification Type was not updated properly when the objects were moved. - Objects in SNMPv1 traps were not being read correctly from a mib that was saved by MIBuilder. version 4.7.3 Feb 3, 2008 - Default window layout short cut changed from CTRL-E to CTRL-W. version 4.7.2 July 18, 2007 - Application was not behaving properly when loading a faulty mib with a syntax that was without a proper import statement - In the Syntax dialog box, the information added for range/sizes got lost when changing the syntax version 4.7.1 November 22, 2006 - Allow the Child Number to be a 2^^31-1 - The ordering is fixed when inserting a node before another one, applies to cut/copy/paste - check to make sure a node can not be added after the largest child number version 4.7.0 September 12, 2006 - Module Identity was not being properly moved. It was being copied instead of moving. It is fixed. - Notification group was not being updated properly if the notification type which was in the notification was deleted. Problem is fixed. version 4.6.1 Nov 22, 2005 - Application was shutting down sometimes on win95 when the syntax button was pressed - Main window coordinates were not being saved when the top coordinate was zero version 4.6.0 Nov 8, 2005 - Copying and Moving a table was not copying the index properly. The bug was introduced in the previous release. version 4.5.5 March 3, 2005 - Added right click menu for expanding / collapsing all nodes - Fixed crash when reading mibs that contained references to itself - Imported mib is not allowed to be deleted if the root is being used from it - Some of the icons in the imported mibs were not being displayed with right colours version 4.5.4 Feb 2, 2005 - Creates a backup .bak file before editing the mib file - provides interface to the user for choosing the mib module to edit in MIBuilder,if the mib file contains multiple mib modules - when a user changes the object name, it will automatically get updated in other syntaxes that use this name - Paste always seemed to be enabled, it has been fixed - copy/paste now properly copies over the defaults, units and prefixes - copying of AgentCapabilities fixed - changing the name of an objecttype gets updated in Groups/Notifications etc. - ASN1 and status windows location is saved and they are placed in the last saved location version 4.5.0 July 13, 2004 - Fixes the problem with property page layout when it is resized - Added right click to the status/property/Asn1 windows for default layout and clearing of status window - Notification to the user if a mib file contains multiple mib modules version 4.4.6 Jan 23, 2004 - Fixes a problem when edit a revision in Module Identity. version 4.4.5 Oct 9, 2003 - Support for the IMPLIED keyword is provided. version 4.4.2 September 1, 2003 - Fixed the problem when the window was resized to the left version 4.4 - Aug 6, 2003 1) Automatic scanning of directories and loading of imported mib module is done 2) Tools/Options has extra tab for handling of directories 3) Comments can be added to the trap/notification types within the constructs for HP openview compatability 4) Defval for scalar and tabular objects 5) Fixed restoring from minimized state 6) Fixed window handle for resizing at the bottom of the window 7) Improved startup window handling 8) Objects can be moved without having the destination siblings automatically reordered. version 4.3.5 - Feb 24,2003 1) Uses different icons for deprecated and optional objects 2) Option for auto ordering of enumerations and bits 3) Fixed the bug when an SMIv1 mib was loaded by double clicking. When a new trap was added to exsiting traps, the application would terminate. version 4.3.4 - Aug 28, 2002 1) More button on Module Compilance properties was hanging the application. It is fixed. version 4.3.3 - July 29, 2002 1) Fixed Module Compliance for properly handling imported modules. version 4.3.1 - May 16, 2002 1) Fixes TC bug introduced in v4.30 version 4.3 - May 3, 2002 1) Syntax dialog box now shows the textual conventions and the modules they belong to. User can which module TC to use. 2) Module Compliance and Agent Capabilities user interface slightly modified. Imported groups can now be chosen in those objects. 3) Fixed the icon for the root version 4.2 - Feb 15, 2002 1) Loads a mib from command line 2) Starts a mib in the correct SMI mode whether v1 or v2 3) Default SMI menu under options is removed 4) New mib will display dialog box for choosing v1/v2 mib 5) New menu under File is added to 'Convert a SMIv1 mib to v2' 6) The key assigned to deleting nodes is changed from shift-del to del 7) Ctrl-c, Ctrl-v implemented for text boxes 8) Find/Find next implemented with case sensitivity and fullname features 9) Check has been changed to Compile 10) Double click on a node 11) Displaying and printing current mib 12) Displaying and printing mib tree 13) Displaying imported mibs 14) Bringing to the front windows from the toolbar 15) Customizing the toolbar by double clicking on it or through the options menu 16) Choosing and saving a mib file in a different style. The choice available in Options menu 17) The treeview now displays the child number as part of the name 18) Color of the root/imported node will also change. 19) The root/imported node will display the full oid in the name as well 20) Default display arrangement of windows 21) Prefix field added to tables and branches 22) Menu item in Edit to modify prefixes in tables and branches 23) Horizontal scroll bar in listboxes and where compile errors are listed 24) Syntax dialog box now hides the choice not useful for a particular syntax 25) Added help buttons in dialog boxes 26) Context Sensitive help 27) Short cut keys added to insert tables/branches/leaves version 4.1 - July 16, 2001 - The display of fonts in impoted texts is fixed. version 4.0 - June 25, 2001 - combining SMIv1 and SMIv2 into a single MIBuilder. - auto loading of dependencies of imported mib. - error editor for imported mib. version 3.6 - Jan 18, 2001 - Every standard mib that has MACROS and syntax, now has an explanation from the relevant mibs. - BITS syntax properly handled. - Buttons (Apply, Cancel etc.) now have short cut keys. - Expanded frame for agent entry so that long names are visible. - Introduced a two pass check for more checking. version 3.5 - December 8, 2000 - Changed the MIBuilder icon - Proper handling of blank lines in description and comment fields version 3.4 - December 4, 2000 - Added functionality to create a MIB tree - incorporated end of file comments - fixed application crash when moving NotifType above or below a node - previous version allowed the notification type to be added to a table - previous version allowed the notification type to be added above or below - a leaf in a table - warning message if unable to write the mib - New mib did not work after saving a mib - eval policy changed to allow the user to save a mib if 15 or fewer nodes - add a tool tip for the index entries - changed the font of the ASN.1 box - fixed the ASN.1 display of imported regpoints version 3.3 - September 5, 2000 - Fix application crash on Module Name - More - Added a string at the end of the MIB - Quick start icon version 3.2 - June 27, 2000 - Reorder children command added - Description and reference of table entry node not copied on copy and move commands - Access of the table index changes from not accessible to read write when moving or copying tables - An option for ordering of tables and leaves added - Allow change to leaf and table node child numbers - When table is copied or moved the auguments gets changed to index - Treevies icons changed - Help updated Version 3.0 - May 29, 2000 - Initial Release